Knauf Partition Wall Systems
Weiter
Partition Wall Systems
-
System
|
Description
|
Download
|
W111
|
W111 partition wall system is installed with single DC stud, at least 12,5 mm thick single layer Knauf Gypsum Board on each side and proper thickness of mineral wool according to the width of DC Stud.
|
Data Sheet
|
W141 DM
|
W141 partition wall system is installed with single DM stud, at least 12,5 mm thick single layer gypsum board or Diamant on each side and proper thickness of mineral wool according to the width of DM stud.
|
Data Sheet
|
W151 Diamant
|
W151 partition wall system is installed with single DC stud , at least 12,5 mm thick single layer Knauf Diamant on each side and proper thickness of mineral wool according to the width of DC Stud.
|
Data Sheet
|
W361 Vidipan
|
W361 partition wall system is installed with single DC stud, one layer Knauf Vidipan at least 12,5 mm thick on each side and proper thickness of mineral wool according to the width of DC stud.
|
Data Sheet
|
W381 Aquapanel
|
W381 Aquapanel® partition wall system is installed with single DC stud, 12,5 mm single layer Aquapanel® on each side and proper thickness of mineral wool according to the width of DC stud.
|
Data Sheet
|
K234 Fireboard
|
K234 Fireboard partition wall system is installed with single DC stud, single layer 20 mm or double layer 12,5 mm Knauf Fireboard on each side and proper thickness of mineral wool inside.
|
Data Sheet
|
system
|
Description
|
Download
|
W112
|
W112 partition wall system is installed with single DC stud, at least 12,5 mm thick double layer Knauf Gypsum Board on each side and proper thickness of mineral wool according to the width of DC Stud.
|
W142 DM
|
W142 partition wall system is installed with single stud, at least 12,5 mm thick double layer gypsum board or Diamant on each side and proper thickness of mineral wool according to the width of DM stud.
|
W152 Diamant
|
W152 partition wall system is installed with single DC stud, at least 12,5 mm thick double layer Diamant Board on each side and proper thickness of mineral wool according to the width of DC stud.
|
W362 Vidipan
|
W362 Vidipan partition wall system is installed with single DC stud, at least 12,5 mm thick double layer Knauf Vidipan on each side and proper thickness of mineral wool according to the width of DC stud.
|
W382 Aquapanel
|
W382 Aquapanel® partition wall system is installed with single DC stud, 12,5 mm double layer Aquapanel® indoor on each side and proper thickness of mineral wool according to the width of DC stud.
|
System
|
Description
|
Download
|
W113
|
W113 partition wall system is installed with single DC stud, at least 12,5 mm thick triple layer Knauf Gypsum Board on each side and proper thickness of mineral wool according to the width of DC Stud.
|
Data Sheet
|
W153 Diamant
|
W153 partition wall system is installed with single DC stud at least 12,5 mm thick triple layer Diamant Board on each side and proper thickness of mineral wool according to the width of DC stud.
|
Data Sheet
|
System
|
Description
|
Download
|
W115
|
W115 partition wall system is installed with double DC stud, at least 12,5 mm thick double layer Knauf Gypsum Board on each side proper thickness of single-or double layer mineral wool according to the width of DC stud.
|
Data Sheet
|
W365 Vidipan
|
W365 Vidipan partition wall system is installed with double DC stud, at least 12,5 mm thick double layer Vidipan on each side and proper thickness of single-or double layer mineral wool according to the width of DC stud.
|
Data Sheet
|
W345 Vidipan
|
W345 partition wall system is installed with double DM stud, 12,5 mm triple layer Vidipan on each side and proper thickness of triple layer mineral wool inside.
|
Data Sheet
|
System
|
Description
|
Download
|
W116
|
W116 partition wall system is installed with double DC stud , at least 12,5 mm thick double layer Knauf Gypsum Board on each side and with proper thickness of single-or double layer mineral wool according to the width of DC stud. The spacing between studs is adjustable according to the quantity of installation pipes and the studs are reinforced with gypsum board strips.
|
Data Sheet
|
W366 Vidipan
|
W366 Vidipan partition wall system is installed with double DC stud, at least 12,5 mm thick double layer Vidipan on each side and proper thickness of single or double layer mineral wool according to the width of DC stud. The spacing between studs is adjustable according to the quantity of installation pipes and the studs are reinforced with Vidipan strips.
|
Data Sheet
|
W386 Aquapanel
|
W386 Aquapanel® partition wall system is installed with double DC stud, 12,5 mm single layer Aquapanel® indoor on each side and proper thickness of single-or double layer mineral wool according to the width of DC Stud. The spacing between studs is adjustable according to the quantity of installation pipes and the studs are reinforced with Aquapanel strips.
|
Data Sheet
|
System
|
Description
|
Download
|
W118 WK2 Diamant
|
W118 WK2 partition wall system is a safety wall, installed with single DC stud, at least 12,5 mm thick double layer Diamant Board on each side, 0.50 mm thick steel sheet between the boards and with proper thickness of thick mineral wool according to the width of DC stud.
|
Data Sheet
|
W118 WK3 Diamant
|
W118 WK3 partition wall system is a safety wall, installed with single DC stud, at least 12,5 mm thick triple layer Diamant Board on each side, 0.50 mm thick steel sheet between the boards and proper thickness of mineral wool according to the width of DC stud.
|
Data Sheet
|
K131 Safeboard
|
K131 Safeboard partition wall system, which is X-ray protection wall, is installed with single DC stud, 12,5 mm single layer Safeboard on each side and proper thickness of mineral wool according to the width of DC stud.
|
Data Sheet
|
K132 Safeboard
|
K132 Safeboard Partition Wall System, which is X-ray protection wall, is installed with single DC stud, 12,5 mm double layer Safeboard on each side and proper thickness of mineral wool according to the width of DC stud.
|
Data Sheet
|
K132D Safeboard+Diamant
|
K132D Safeboard partition wall system, which is X-ray protection wall, is installed with single DC stud, 12,5 mm single layer Safeboard and 12,5 mm single layer Diamant on each side and proper thickness of mineral wool according to the width of DC stud.
|
Data Sheet
|
K133D Safeboard+Diamant
|
K133D Safeboard partition wall system is X-ray protection wall, installed with single DC stud, 12,5 mm double layer Safeboard and 12,5 mm single layer Diamant on each side and proper thickness of mineral wool according to the width of DC stud.
|
Data Sheet
|