Knauf Ceiling Systems

System Description Downlaod
D112 D112 Gypsum Board suspended ceiling system is installed by using hanger system suitable for the ceiling
load, main and furring TC channels which are connected to each other with intersection connectors, at
least 12,5 mm thick single, double or triple layer Knauf Gypsum Board and with proper thickness of
mineral wool which is determined according to the sound insulation and fire resistance requirements.
Data Sheet
D112A Aquapanel D112A Aquapanel® suspended ceiling system is installed by using hanger system suitable for the ceiling
load, main and furring TC channels which are connected to each other with intersection connectors,
at least 12,5 mm thick single layer Aquapanel® and single layer Fire Resistant Gypsum Board (FR) or two
layers Knauf Aquapanel® and mineral wool with 40 mm thickness which is determined according to the
sound insulation and fire resistance requirements.
Data Sheet
D112AS Aquapanel Skylite D112AS Aquapanel® suspended ceiling system which is an under canopy ceiling system, is installed by
using hanger system suitable for the ceiling load, main and furring TC channels which are connected to
each other with intersection connectors, single layer 8 mm Aquapanell® Skylite or 12,5 mm Aquapanel®
and with proper thickness of mineral wool which is determined according to the sound insulation and fire
resistance requirements.
Data Sheet
D116 UA Profil D116 suspended ceiling system which has an enhanced load bearing capacity, is installed by using
hanger system suitable for the ceiling load, main channel with UA profile and furring TC channels which
are connected to each other with intersection connectors, at least 12,5 mm thick single, double or triple
layer Knauf Gypsum Board and mineral wool with proper thickness which is determined according to the
sound insulation and fire resistance requirements.
Data Sheet
D127 Acoustic D127 Cleaneo suspended ceiling system is installed by using hanger system suitable for the ceiling
load, main and furring TC channels which are connected to each other with intersection connectors,
12,5 mm single layer Knauf Cleaneo and with the 20 mm thick mineral wool to provide the sound
absorption requirements.
Data Sheet
K112 Safeboard K112 suspended ceiling system which has X-ray protection properties, is installed by using hanger
system suitable for the ceiling load, main and furring TC channels which are connected to each other with
intersection connectors, 12,5 mm single, double or triple layer Safeboard which are determined according
to the radiation value in the area and proper thickness of mineral wool which is determined according to
the sound insulation and fire resistance requirements.
Data Sheet
K214 Fireboard K214 Fireboard suspended ceiling system is installed by using hanger system suitable for the ceiling load,
main and furring TC channels which are connected to each other with intersection connectors, 20 mm
double layer Fireboard and with the 40 mm thick mineral wool which is determined according to the sound
insulation and fire resistance requirements.
Data Sheet
K215 Fireboard K215 Fireboard Fire Resistant suspended ceiling system is installed by using hanger system suitable for
the ceiling load, main and furring TC channels connected to each other with intersection connectors and
at least 12,5 mm thick single layer Fireboard.
Data Sheet

System Description Download
D113 Equal Level D113 suspended ceiling system is installed by using hanger system suitable for the ceiling load, main
and furring TC channels which are connected to each other with flush connectors, at least 12,5 mm thick
single, double or triple layer Knauf Gypsum Board and with proper thickness of mineral wool which is
determined according to the sound insulation and fire resistance requirements.
Data Sheet

System Description Download
D115 D115 Ceiling Under Ceiling; is installed by using hanger system suitable for the ceiling load, main and
furring TC channels which are connected to each other with intersection connectors, min. 12,5 mm thick
single, double or triple layer Knauf Gypsum Board and is fixed under the fire resistant suspended ceiling
system for decorative designs or for providing acoustical values.
Data Sheet

System Description Download
D131 D131 free spanning (hanger free) suspended ceiling system which is determined according to the size of the
place it is going to be used, is installed by using wall DC studs fixed to each other from the back sides and
at least 12,5 mm thick single or double layer Knauf Gypsum Board and proper thickness of mineral wool which
is determined according to the sound insulation and fire resistance requirements.
Data Sheet
K219 Fireboard K219 free spanning (hanger free) Fireboard Fire resistant suspended ceiling system which is determined
according to the size of the place it is going to be used, is installed by using DC wall studs fixed to each
other from back sides and 20 mm double layer Fireboard.
Data Sheet

System Description Download
T Grid System Modular suspended ceiling with T grid system is installed by using mineral wool, gypsum board, metal
ceiling tiles and T15 or T24 carriers which are suitable for the tiles.
Data Sheet
Clip-in System Clip-in Modular suspended ceiling system is a concealed suspension system installed by using metal
ceiling panels and Clip-in carriers.
Data Sheet