W611 W611 Gypsum Board Drywall Lining System is installed by applying single layer Knauf Gypsum Board
with minimum thickness 9,5mm on the existing walls with Yapıgips gypsum based adhesive.
Data Sheet
W624 W624 drywall lining system is installed with applying layer 12,5 mm Gypsum Board which is laminated
with 20/30/50 mm mineral wool, on the existing walls by using Yapıgips adhesive in order to increase the
thermal insulation values of the existing walls.
Data Sheet
W631 W631 drywall lining system is installed with applying single layer 9,5/12,5 mm Gypsum Board which is
laminated with 20/30/40 mm EPS, on the existing walls by using Yapıgips adhesive in order to increase
the thermal insulation values of the existing walls.
Data Sheet

System Description Download
W623 W623 Gypsum Board Drywall Lining System is installed on the existing wall with direct hanger, Ceiling C
and U channels with single or double layer 12,5 mm Gypsum Board and in between mineral wool in order
to fulfill the sound and thermal insulation requirements.
Data Sheet
W623A Aquapanel W623A Aquapanel® Drywall Lining System is installed on the existing wall with direct hanger, Ceiling C
channel and Ceiling U channel with 12,5 mm single layer Aquapanel® and in between mineral wool in
order to fulfill the sound and thermal insulation requirements.
Data Sheet
W623C Cleaneo W623C Cleaneo Drywall Lining System is installed on the existing wall with direct hanger, Ceiling C
channel and Ceiling U channel with single layer Cleaneo according to the required area and single layer
12,5 mm Knauf Gypsum Board (double layer where Cleaneo is not applied) and in between mineral wool
in order to fulfill the optimum sound absorption requirements.
Data Sheet

System Description Download
W625 W625 Gypsum Board Drywall Lining System is installed with DC stud and DU channel which are located
separate from the wall and with 12,5 mm single layer Knauf Gypsum Board and in between mineral wool
for fulfilling thermal insulation and fire resistance requirements.
Data Sheet
W626 W626 Gypsum Board Drywall Lining System is installed with DC stud and DU channel which are located
separate from the wall and with 12,5 mm double layer Gypsum Board and in between mineral wool for
fulfilling thermal insulation and fire resistance requirements.
Data Sheet
W625A Aquapanel W625A Aquapanel® Wall Cladding System is installed with DC stud and DU channel which are located
separate from the wall and with 12,5 mm single layer Knauf Aquapanel® and in between mineral wool for
fulfilling thermal insulation and fire resistance requirements.
Data Sheet
W629C Cleaneo W629C Cleaneo Drywall Lining System is installed with DC stud fixed from the back sides and DU channel
which are located separate from the wall and with single layer Cleaneo according to the required area and
single layer 12,5 mm Gypsum Board (Double layer where Cleaneo is not applied) and in between mineral
wool in order to fulfill the optimum sound absorption requirements.
Data Sheet