System | Description | Downlaod |
---|---|---|
D112 | D112 Gypsum Board suspended ceiling system is installed by using hanger system suitable for the ceiling load, main and furring TC channels which are connected to each other with intersection connectors, at least 12,5 mm thick single, double or triple layer Knauf Gypsum Board and with proper thickness of mineral wool which is determined according to the sound insulation and fire resistance requirements. |
Data Sheet |
D112A Aquapanel | D112A Aquapanel® suspended ceiling system is installed by using hanger system suitable for the ceiling load, main and furring TC channels which are connected to each other with intersection connectors, at least 12,5 mm thick single layer Aquapanel® and single layer Fire Resistant Gypsum Board (FR) or two layers Knauf Aquapanel® and mineral wool with 40 mm thickness which is determined according to the sound insulation and fire resistance requirements. |
Data Sheet |
D112AS Aquapanel Skylite | D112AS Aquapanel® suspended ceiling system which is an under canopy ceiling system, is installed by using hanger system suitable for the ceiling load, main and furring TC channels which are connected to each other with intersection connectors, single layer 8 mm Aquapanell® Skylite or 12,5 mm Aquapanel® and with proper thickness of mineral wool which is determined according to the sound insulation and fire resistance requirements. |
Data Sheet |
D116 UA Profil | D116 suspended ceiling system which has an enhanced load bearing capacity, is installed by using hanger system suitable for the ceiling load, main channel with UA profile and furring TC channels which are connected to each other with intersection connectors, at least 12,5 mm thick single, double or triple layer Knauf Gypsum Board and mineral wool with proper thickness which is determined according to the sound insulation and fire resistance requirements. |
Data Sheet |
D127 Acoustic | D127 Cleaneo suspended ceiling system is installed by using hanger system suitable for the ceiling load, main and furring TC channels which are connected to each other with intersection connectors, 12,5 mm single layer Knauf Cleaneo and with the 20 mm thick mineral wool to provide the sound absorption requirements. |
Data Sheet |
K112 Safeboard | K112 suspended ceiling system which has X-ray protection properties, is installed by using hanger system suitable for the ceiling load, main and furring TC channels which are connected to each other with intersection connectors, 12,5 mm single, double or triple layer Safeboard which are determined according to the radiation value in the area and proper thickness of mineral wool which is determined according to the sound insulation and fire resistance requirements. |
Data Sheet |
K214 Fireboard | K214 Fireboard suspended ceiling system is installed by using hanger system suitable for the ceiling load, main and furring TC channels which are connected to each other with intersection connectors, 20 mm double layer Fireboard and with the 40 mm thick mineral wool which is determined according to the sound insulation and fire resistance requirements. |
Data Sheet |
K215 Fireboard | K215 Fireboard Fire Resistant suspended ceiling system is installed by using hanger system suitable for the ceiling load, main and furring TC channels connected to each other with intersection connectors and at least 12,5 mm thick single layer Fireboard. |
Data Sheet |